--- title: "Microdrive Stretch" type: "article" slug: "microdrive-stretch" url: "http://localhost/article/microdrive-stretch/" markdown_url: "http://localhost/article/microdrive-stretch.md" published_at: "2026-11-21T22:03:38+00:00" modified_at: "2026-11-21T22:56:23+00:00" featured_image: url: "http://localhost/wp-content/uploads/2022/04/20230809-041332.jpg" excerpt: "Bob Dyl recommends \"stretching\" your micro drive cartridge. His group feels that they've gained at least 1 or 2K per cartridge by using the following program: 10 For I = 1 to 10 20 Format \"m\";1;\"Test\" 30 Next I 40 Cat 1 We tested Bob Byl's program for microdrive cartridges \"stretching\" and found the following:…" post_tag: - name: "Full Text" slug: "fulltext" taxonomy: "post_tag" url: "http://localhost/tag/fulltext/" - name: "Microdrive" slug: "microdrive" taxonomy: "post_tag" url: "http://localhost/tag/microdrive/" - name: "Type-in program" slug: "type-in-program" taxonomy: "post_tag" url: "http://localhost/tag/type-in-program/" - name: "ZX Spectrum" slug: "zx-spectrum" taxonomy: "post_tag" url: "http://localhost/tag/zx-spectrum/" model: - name: "Sinclair ZX Spectrum" slug: "zxspectrum" taxonomy: "model" url: "http://localhost/model/zxspectrum/" indiv: - name: "Bob Dyl" slug: "bob-dyl" taxonomy: "indiv" url: "http://localhost/indiv/bob-dyl/" publication_r: id: 38992 title: "LISTing Newsletter" type: "periodical" url: "http://localhost/periodical/listing-newsletter/" issues_articles: - id: 78308 title: "LISTing Newsletter May – June 1985" type: "issue" url: "http://localhost/issue/listing-newsletter-may-june-1985/" pages: "21" pubdate: "May - June 1985" archive_link: false --- # Microdrive Stretch [Bob Dyl](http://localhost/indiv/bob-dyl/) recommends “stretching” your micro drive cartridge. His group feels that they’ve gained at least 1 or 2K per cartridge by using the following program: ``` 10 For I = 1 to 10 20 Format "m";1;"Test" 30 Next I 40 Cat 1 ``` We tested Bob Byl’s program for microdrive cartridges “stretching” and found the following: ``` FORMAT FIRST MIN FORMAT MAX FORMAT FINAL a 11* 89 89 89 b 89 89 89 89 c 90 89 90 90 d 88 87 88 88 e 89 88 89 88 f 85 85 86 86 g 88 87 88 88 h 87 87 87 87 i 89 88 89 89 k 90 90 91 91 ``` * On Start up (assume 89) So of 10 tapes the average (true) starting number of free bytes was 88.4. After repeated formatting we got an average of 88.5 although I found that manually FORMATTing and CATaloging allowed me to stop the process at a high level. A typical stream of results was: ``` FORMATTED i 1 time 89 2 times 88 3 89 4 88 5 89 6 88 7 89 8 88 9 89 10 88 Manually 89 STOP. ``` My conclusion, with a lot of time on your hands and wear and tear on the microdrive, you might be able to to eek out 1K more from most cartridges.