QL CORNER
GUIDE TO TROUBLE SHOOTING
Not too many years ago, when computers were made of wired keyboards and any number of discrete boards, fault-finding was a little easier for the layman. If a faulty board could be found it could be removed and replaced, a relatively inexpensive job.
The QL has a membrain keyboard, internally, and only one board. The memory chips are soldered in and the microdrive cartridge mechanism is part of the case, and the microdrive recording heads are not adjustable.
Those are, of course, some of the features which permit such a powerful computer to be sold at such low cost, so we can hardly complain.
This implies that fault finding and repair work by the knowledgable owner is a little more difficult. One big handicap is that no circuit diagram is supplied with the QL as standard. It is suggested that unless you have a good deal of experience of repair work, a QL service manual is essential. Custom chips; the ZX 8301 and ZX 8302 can be obtained from Sharps if needed.
If you do not feel confident about attempting a repair yourself, I believe that Dan Elliot still repairs Timex/Sinclair computers. If you could be specific about a fau;t, say, a microdrive is not working properly. Ask yourself, in what way(s) is it not working? If the QL continuously locks up, is there a good reason for the lock-up? By looking carefully at the options you may save yourself a repair bill. Let us consider a number of common fault areas in the QL.
The following table lists faults against possible problems. The list of numbers relates to the actions you can take to cure a fault or check the area where it lies. The related actions are listed below this table.
FAULT CAUSE CHECK
Green/white screen on power-up Faulty expansion 1,2
or re-set. port or RAM.
Large Blocks/stripes of color Chip or bad chip 3
and possible speaker noise. pin contact.
No re-set or spurious re-sets Faulty re-set 4,5
occurring. switch.
QL locks-up after specified Overheating/ 3,6,7,8
time. bad contacts/
noisy A-C or
marginal RAM.
QL locks-up at random. Noisy A-C/bad 3,7,8
contacts or
marginal RAM.
Microdrives fail to read/ Noisy A-C or 6,7
write properly on a cart- over-heating.
ridge in use in one drive
only.
Microdrive fails to read Bad alignment. 9
cartridges recorded by
another drive.
Microdrive fails to read/ Over-heating/ 3,6,
write any cartridge. bad pin con-
tacts or faulty
drive.
Certain keys; not usually Faulty keyboard 10
the complete set; fails to membraine.
operate.
1. Remove any expansion module and check operation. If the fault is cured the expansion module is faulty or requires too much power from the QL.
2. External RAM is faulty. Treat as for number 1 above.
3. Bad chip contacts can be checked and cleaned only by removing all possible chips – not the ones soldered in – from the main board. Do not perform this unless you are confident and obey all normal rules regarding static-sensitive devices.
4. Re-set switch has been damaged by upward pressure while using it. Check state of switch by removing QL lid.
5. Power plug connections are weak through too much use. Replace or hard wire power lead.
6. Over-heating; keep away from direct sunlight and other heat sources. Do not cover vent holes. Remove any expansion boards to see if they are drawing too much power from the QL. Place small silent fan behind right-hand-side of machine or, if confident – and as a last resort – remove the voltage regulator and heatsink to the outside of case.
7. Noisy A-C power line. This can be rectified by using suppressor module.
8. If QL contains marginal or ‘lossy’ RAM, a full RAM test will be needed to check operation of RAM.
9. If microdrive heads are mis-aligned, there is little hope of cure except by a complete replacement.
10. Replace faulty keyboard membraine.
QL CORNER
Archive: Watch the saves
Archive file saving options, although similar, work in different ways. If you produce a collection of PROCedures and input “SAVE drive filename” (save flp2_procedures), the procedures will be saved as a text file which will be appended with “_prg“. Loading this type of file back into Archive is similar to loading a SuperBASIC program; it is slow.
Saving the procedures using the “SAVE OBJECT drive filename” will save the file in a tokenized form used internally by Archive. The process is roughly analogous to compiling a Basic program. This type of file is appended with “_pro“, and takes up more media space, but can still be modified after re-loading it into Archive.
If a file is saved with the command “SAVE PROTECT drive filename“, it is also appended with “_pro“, but cannot be listed or modified in any way.
This type of file should be used only:
a] if you have spent a considerable amount of time developing meaningful Archive routines which you want to protect; and
b] only if you are very sure that you will not want to modify them at some future date; and
c] only if you have also saved them as “_prg” files as well.
With the possible exception of accessibility and loading time for a large PROCedure file, the end-user is unlikely to notice any difference between either of the three SAVE variations. 1/20/91