QL CORNER
This months article has been inspired by Harvey Rait, President of the LIST Group. Harvey’s QL power supply failed and he asked me if I could repair the power supply for him. The only problem that I had was opening up the supply case.
I was able to remove two out of the four, cross-slotted screws, destroying two screw drivers during that process. Fred Stern took the power supply home; drilled out the remaining screws and delivered the supply to me via Bob Malloy. This was a real team effort and this is just what LIST is all about!
The Power Supply consists of a small printed circuit board attached to eight transformer windings. First, I checked the output voltage from the line delivering 9 – 12 VDC to the internal QL regulator (the RED lead). The voltage reading was approximately +5 Volts DC, much too low! The first check was to determine if the four rectifier diodes were OK. Using an OHM meter I checked each of the four 1N5400 diodes, back to back. One of the diodes appeared to be shorted, so I removed all four of them and then checked them in both directions with an OHM meter. One diode was shorted and another diode displayed some leakage.
I replaced the two original good diodes and installed two new diodes (1N5401, 100 Volt rating) into the printed circuit board and then tested the output for proper voltage. The supply output indicated +11.5 VDC unloaded (with out the cable attached to the QL). The Power cable was then connected to a QL and when powered up the QL responded as it should.
Some words of caution about reparing the QL power supply: The printed circuit board is made from phenolic resin PC material with a thin copper overlay. This type of PC material is prone to warps and cracking. If you have to remove any of the SIX diodes on the board, use a hot soldering iron and some sort of desoldering tool to pry the diodes out. The diode leads are approximately 1/16″ in diameter, heavier than most components you will encounter. Before you reinsert the original diodes into the PC board, carefully file off any burrs and excess solder coating on the diode leads so that they fit into the PC board holes easily – otherwise if you apply too much pressure on the diodes during insertion and the leads aren’t smooth, the chance of lifting up the foil trace on the PC board is great, making not only the repair difficult but having to repair the broken trace by adding a short length of tinned wire across the fractured trace.
I tested Harvey’s Power Supply unloaded, in other words, it was not connected to the QL before I was sure that the voltage for the QL internal voltage regulator fell between +11 – +12VDC. Once the proper unloaded voltage fell within the above stated range; then I disconnected the power cable from the AC source; connected the cable to the QL and then powered up the supply for testing.
I made an attempt to adjust the 2K2 (2.2K) variable control for a slightly higher voltage output. To my surprise, the control was sealed with a solvent preventing any adjustment of the control. The power supply was then reassembled into the case and I used 4-40×1/2″ machine screws as a replacement for the original screws.
Next month I will supply the printed circuit board layout, a component placement layout , a list of components indicating both US and European equivalents and a schematic for the power supply. I will also list voltage measurement points at all component junctions on the PC component layout and if I have the room, I will attempt to provide a simplified theory for the QL power supply.
See you next month…. Bon Gilder