The Cassette Connection

Author(s): Fred Nachbaur
Publication: ZX-Appeal
Pub Details: ZX-Appeal Summer 88
Date: Summer 1988
Pages: 10-11

In Volume 1, I ran a series on improving cassette reliability on the ZX81. Well, now that the TS2068 has arrived, that’s all obsolete, right? Wrong! If anything, in my experience the 2068 needs even more “outside help” in getting reliable loads.

First, let’s take a look at the load signal itself. As you may have noticed, the actual program is preceded by a header which consists of about five seconds (4032 cycles) of an 806.5 Hz. tone. This “sync pattern” is presumably used to set timing and compensate for variations in recorder speed. This is followed by:

1. The type of save (program, numeric array, string array or code)

2. A name up to 10 characters

3. The length of the file

4. The starting line number, variable array or address

5. Then (in the case of program saves) the offset to the variables (VARS-PROG).

After the header is a brief silence (though I use that term loosely), followed by another 5 second sync pattern and the actual program or data. (This info is from the tech manual.)

The data is represented quite differently from the ZX81/TS1000. Instead of having pulses of fixed width, with five such pulses representing a “0” and nine pulses being a “1”, the TS2068 uses the more conventional approach of sending a short pulse (period=.48 ms) for zeros, and a longer pulse (period=.96 ms) for ones. This is, by the way, the same kind of system used by SDS, Z-XLR8 and other fast-load programs for the ZX81. Although it is about four times as fast as the standard ZX81 load routines, it is still considerably slower than the “fast-load” routines; the average rate of data transfer is about 1400 baud (bits per second) whereas SDS, for instance, runs at about 3500 baud and Z-XLR8 is variable up to about the same speed.

According to the tech manual, the SAVE signal is processed with a low-pass filter whose corner frequency is 2.5 KHz., which is very close to the output frequency when sending all zeroes. As a result, the signal is considerably “rounded” before it gets to the recorder. This may help in preventing overshoots and harmonic effects (“beating” with the bias oscillator in the recorder), but it tends to make the signal mushier and less sharply defined in pulse-width. As a side note, the manual also claims that the SAVE signal is between 0.15 and 0.67 V p-p; if this were so, your recorder would be blasted so badly you’d only get garbage. Perhaps this refers to the signal at the edge connector, or perhaps they meant 0.15 – 0.67 MILLIvolts (.00015-.00067 V).

The LOAD section is low-pass filtered at a much higher breakpoint (23 kHz.), so the effect this filter has on the load signal is negligible; it would not even significantly reduce any horizontal blanking pulses that might find their way to the tape. The sensitivity of the LOAD section is even less than the ZX81/TS1000, so a comparator or op-amp pre-conditioner is definitely recommended for this machine. Also, because of the extreme rounding of the save signal, volume setting is more critical; the range over which the pulse width is within acceptable limits is quite narrow, even with a pre-conditioner.

Now the Good News!

Now, the good news. There is an almost absurdly simple way of fixing this.

1. Remove the 7 screws that hold the two case halves together, gently separate them and unplug the keyboard.

2. Remove the three screws that hold the board to the lower case-half, one near the speaker, one near the “Timex 2000” logo and one next to the cartridge connector.

3. Lift the board out and turn it over.

4. Shunted directly across the MIC jack, on the wiring side of the board, you’ll find a small blue (on my machine) 120 pF. capacitor. Remove it, and throw it into your junk box. (Who knows, it might be useful for something.) This alone might do it.

5. There is another identical cap in parallel with this one, located about 2″ to the left of the CPU and just to the left of an LS245 (U15). It is marked C10, though the legend may be hard to see; it’s the smaller one, at the bottom of a row of components. Clip this one also.

6. Re-assemble the machine, and you’re done.

Before I performed these “cap-ectomies” on my machine, I couldn’t load tapes I’d saved on the TS2020 recorder, though other recorders worked sometimes. Now it works just fine, and is less sensitive to variations in playback level. What we’ve done is remove that low-pass filter and squared the save signal back up. It is unclear why C10 was included and downright obscure why another one was tacked on afterwards. Perhaps they were afraid of too much RFI and possibly flunking FCC testing.

TS2068 board sketch showing the capacitors to clip (C10 near the LS245)
TS2068 board sketch showing the capacitors to clip (C10 near the LS245)

If this results in too much noise on your machine, or if it didn’t improve matters any, put one of the caps back in and try it again. It could be that you’re getting harmonic “beating” with the recorder’s bias oscillator. If you still have no joy, your problem is most likely with the load, rather than the save. Try a Winky board, VOTEM, the circuit in Volume 1 or other load signal pre-conditioner.

Reprinted by permission from SyncWare News Vol2 #3