The Digitizer and A Problem Found

See all articles from Sinc-Link v9 n1
Author(s): Marty Miller
Publication: Sinc-Link
Pub Details: Sinc-Link v9 n1 (Volume 9, Issue 1)
Date: January/February 1991
Pages: 23

By now there are several of you playing around with the digitizer board. Some of you have had great pictures created and some are getting a black scan after 3 to 7 passes. I myself was getting a black scan just by bringing my hand NEAR the board. All is not lost. I have found the problem on the board. Somehow when the boards were made a foil run was omitted & that’s causing this problem. Please refer to the schematic diagram and note that pins 1 & 20 are BOTH tied to the 5 volt line. On the board a jumper on the component side was omitted. This can easily be corrected. Hold the board in your hand with the component side away from you and refer to the layout diagram. IC6 is the IC in the lower right hand corner & pins 1 & 20 are the pins at the bottom. Add a bridge of solder from the open bottom pin to the foil run connecting the other bottom pin and you are all set. If you have any doubts about doing this feel free to return the board to me c/o SMUG, P.O. Box 101, Butler [illegible] 53007, and I will correct it for you.

I still do not know why these boards worked at all. With that pin floating in space the 8 flip-flops in the 74HCT273 could Clear whenever they felt like it. Well I guess I’ll see some of you at the Expo. Right now I am going to get started on trying out John McMichael‘s “VIDEOTEX” program using the OKIMATE 20 color printer to colorize some of these pictures I’ve digitized.

Marty Miller.