While I was on a business trip to Europe last December, I purchased a ZX Spectrum computer. No, I’m not tired of my TS2068, but my first love is my soldering iron and a heap of electronic components with a burning desire to experiment with these electronic marvels we call computers.
The TS2068 and the ZX Spectrum are closely related in design, however there are physical and electronic differences between both computers. Many European publications provide a store of add-on do-it-yourself hardware articles to enhance the Spectrum, but NOT The TS2068. My Spectrum will now become a test bed for building Spectrum hardware, then modifying the hardware to operate with the TS2068.
This article is dedicated to those individuals who have a Spectrum or intend to purchase one and want to get the most out of it – to operate on 110 volts without a step-up transformer; convert the PAL decoder to operate on NTSC video standard for colour operation; and add a composite video output for your monitor.
POWER SUPPLY CONVERSION
The orinal Spectrum power supply module requires 220 VAC at the primary, and outputs approximately 9-10 VDC. Two options for the modification can be considered.
1 – Rewind the original transformer primary winding to operate at 110VAC, or adding additional windings to the secondary to up the output voltage, using the original primary windings. The transformer design allows fairly easy rewinding of the primary or secondary, but it is work.
2 – Remove the original transformer and replace it with a commercial 110 VAC,18 VAC Centre Tap transformer.
I chose option two because I had an 18 VAC CT transformer on hand that fit into the Spectrum power supply case. The reason a 18 VAC CT transformer was selected, is that a 9-10 volt transformer is pretty hard to come by, and by cutting the transformer centre tap and paralleling both 9 volt windings with proper phasing, the voltage is 9 volts with the operating current doubled. Also the original power supply rectification and filter assembly can still be used without modification.


The first step in this operation is to remove the power supply case top by removing three (3) Philips head screws. Remove the case top and set aside with the three retaining screws previously removed. Carefully remove the transformer with the filter assembly and both input and output cables. Measure the transformer core (metal laminations) for height, width, and length and record these measurements. I used an old Radio Shack transformer, however I’m not sure it is still available. A visit to any electronics TV supply house will provide you with the necessary tranformer. Ask for an 18 Volt Centre Tap, 1 amp filament Transformer, and measure it so that what you buy will fit the case. Surgery on the transformer first begins with removal of the mounting frame. Set the transformer on your work bench upside down and pry up the four (4) retaining tabs on the bottom of your transformer core. With a common screwdriver (flat blade), insert the blade between the mounting frame and the transformer core and apply a prying motion until the frame has exposed both sides of the transformer core. Remove the frame from the core and trial fit the tranformer into the power supply case. If the fit is a little loose, a strip of foam tape (weather stripping) will snug things up at assembly time.
Remove the transformer from the case and locate the secondary side. This is the side with either two green lugs and one lead with stripes, or three solder lugs. With a sharp knife (X-ACTO, #11 blade) or razor blade, using light cutting pressure, cut a slit from top to bottom at the centre point on the transformer secondary side insulation. Carefully pull both sides of the cut tape towards their respective sides which should expose three copper wires either terminated to lugs or wires.
Using the low wattage soldering iron, desolder the centre tap winding from a lug or wire. Examine the copper wire tap; it can be either a loop, or two separate wires. If it is a loop, cut the loop, and if it is two wires, separate them. Cut two small strips of tape, any kind, and place one strip on one of the centre tap wires. This is for identification purposes only, to properly phase both both secondary windings which we will parallel. Using an ohmmeter or a continuity tester, connect one lead of the test instrument to the CT lead having the strip of tape. The other test lead is touched to either or both lugs/wires to locate the mating lead of the CT winding having the tape. Now, follow this carefully. Place the other strip of tape on the lug/lead which did NOT indicate continuity. Connect both taped wire ends together, remove both strips of tape and solder these leads together. Connect the remaining two leads together and solder these as you had soldered the others.
Before going further, the transformer output voltage must be tested for a voltage and correct phasing. Connect a two wire cable with a proper 110 VAC connector to the transformer primary. The primary side should state 110 VAC or have two black wires attached to it. Insulate these connections to avoid any contact with the line voltage. Set your voltmeter function switch to AC and the range switch to 25-50 VAC. Plug the line cord into an AC wall outlet and touch both secondary connections with the voltmeter test probes. If the voltmeter is reading 9 VAC or higher then all is well. On the other hand, if no voltage is present, then remove the line cord from the wall socket, desolder the secondary connections previously made and switch secondary leads. Repeat all previous steps until proper AC voltage os obtained.
Attach two 2″ leads to the secondary contacts and solder, then place some insulating tape over the exposed secondary leads. Place the transformer into the bottom of the case and add some foam-backed tape to it if the fit is too loose.
Desolder the filter assembly circuit board from the original transformer and place in the case next to the transformer secondary. Connect both secondary wires to the filter circuit board in the holes which the original transformer was soldered to. Any wire can connect to either hole for tranformer connection. If you wish, the AC line strain relief from the original transformer can be removed and the 110 VAC line cord can be inserted into it for a custom fit.
Set the function switch on your voltmeter to DC and the range switch to 25 VDC. Plug the line cord into the AC socket and monitor the output voltage at the power supply connector. A reading of 9 VDC or greater will be present.
NTSC COLOUR OUTPUT
The Spectrum operates on a European video standard called PAL, which means Phase Alternating Lines. PAL provides 625 TV lines as opposed to 525 TV lines with NTSC. The colour is automatically corrected at trasnmission, thus eliminating the requirement for a Tint or Hue control. If we operate the Spectrum without a change in colour burst frequency, then the output on a TV screen will be black and white, and possibly some diagonal lines. Fortunately a crystal change from 4.43 MHz to 3.57 MHz is all that is necessary to have the Spectrum perform in colour in the USA.
A trip to your local Radio Shack should solve the crystal requirement. Ask for part No. 272-1310, COLORBURST CRYSTAL at $1.69. If they do not have the crystal, any TV or Electonic Supply outlet will have one. Just make sure it is a miniature case, HU-18.
Please note there are two (2) crystals in the Spectrum computer. A 14 MHz crystal operates the system clock and should not be removed or replaced with a crystal of another frequency. The PAL crystal, 4.43 MHz is the one to replace.
Open the Spectrum case by removing five (5) Philips screws on the case bottom. Carefully open the keyboard section of the case and locate a Philips screw approximately centre on the PC board. Remove this screw and lift out the PC assembly with the keyboard still attached. If you are careful, you will not have to remove the keyboard case section.
The 4.43 MHz crystal is located next to the TV RF modulator. Ensure that you have located the right crystal as the clock crystal shares the same approximate location. Heat up your soldering iron and grasp the 4.43 MHz crystal with two fingers. Disconnect the soldering iron from the AC line, and quickly heat up one crystal lead and gently pull with a slight twist at the crystal. Repeat the previous step until the crystal is removed. Note: the soldering iron will not zap any semiconductor within the crystal circuit with a static charge, if disconnected from the AC. Plug the soldering iron back into the AC line to build up heat. Insert the 3.57 MHz crystal into the PC board using the same holes as the crystal you previously removed. Again, disconnect the soldering iron, and quickly solder both crystal leads to the PC board. Clip oof both leads of the crystal on the underside of the board. Place the PC assembly with the keyboard into the lower case.
Attach a cable to the modulator jack and the other end to the UHV leads on a TV set. The approximate channel should be between 30 and 36. Plug in the modified power supply and turn on your TV. Rotate your Channel Select switch until the Sinclair copyright message appears on your TV. If you do not wish to add a Video Monitor output to your Spectrum at this time, then disconnect power and the TV cable, and reassemble the computer case.
NOTE: My Spectrum did not have a trimmer capacitor in the crystal circuit. If yours does and the image on the TV screen appears poor, then you may want to attempt to adjust the trimmer to peak the picture.
This article appeared in an old issue of the L.I.S.T. newsletter, and has no credit line. I suspect it may have been written by Nazir Pashtoon. I have retyped it, since my copy is in poor condition. G. Chambers