| Title | Author(s) | Publication | Date |
|---|---|---|---|
| A Simple Loading Aid Plans for a small device to monitor signal levels when loading programs. | T-S Horizons | January/February 1984 | |
| Back-up system for data THIS unit, called the ZX-99 RS 232C & Tape Control System is designed for the person needing large data-base capabilities.... | Timex Sinclair User | June 1983 | |
| Cassette Notes Tape cleaning and adjustment suggestions. | T-S Horizons | May/June 1985 | |
| FASTLOAD Review of the program. | T-S Horizons | March 1984 | |
| File Protection Recommendation, along with a short subroutine to support it, for saving programs and data to alternating sides of a cassette... | T-S Horizons | January/February 1984 | |
| Follow our golden rules for better SAVEs and LOADs Programming on the T/S1000,ZX81 can be frustrating. These 10 tips should help you get over some of the problems! For... | Timex Sinclair User | June 1983 |
Products (32)
| Title | Company |
|---|---|
| Abacus Controller for TS1000 Eliminate swapping of plugs when LOADing and SAVEing programs on cassette. Single switch selection of TALK, SAVE, CUE, and LOAD... | Abacus Electronics |
| Abacus Controller for TS2000 Eliminate swapping of plugs when LOADing and SAVEing programs on cassette. Single switch selection of SAVE, LOAD, and AMP modes.... | Abacus Electronics |
| Cassette Interface Optional LED indicator. | Phoenix Engineering Systems |
| Cassette loading monitor Digital VU meter. Hooks up in seconds outside the computer; helps ensure proper loading level. | Edson Electronics |
| Cassette output level setting Schematic for precision setting of cassette output level. | Arnold J. Gold |
| Complete LOAD and SAVE Plans Documentation packet that covers troubleshooting tips and plans for LOAD monitor and signal filtering. | Spectra Computer Products |
| Data Conditioner II Tape loading aid. Accurate volume control setting, easy tape cueing, use remote feature. | Communications System Laboratories |
| In-Line Load Monitor Tape loading aid. Helps to LOAD prerecorded software from cassette. | M. C. Hoffman |
| L-Monitor Multipurpose tape loading aid assures LOADing. Features extremely sensitive, reliable microammeter. Output for earphone, amplifier, or duplicating. | L-Monitor |
| Loading Aid Removes guesswork from adjusting cassette recorder volume. Optimum level attained when red and green LEDs flash in unison. Plugs between... | Fulcrum Products |
| Loading monitor LED cassette loading monitor. | R. H. Enterprises |
| Loadstar Calibrated distortion free tape loading amplifier for all tape machines. Triple LED displays for low, normal, overload. Connects between tape... | Cinevision System |
| QSave LOAD/SAVE a full 16K in 29 seconds (16 times faster). QSAVE amplifier/filter unit plugs between recorder and computer. A data... | Personal Software Services |
| RZ1 tape controller Allows control of the SAVE and LOAD leads as well as the tape motor for one or two tape recorders.... | Stephen Adams |
| Speedload Cartridge and flexible extension cable. Program in ROM speeds up load, promised to load a 5 minute program in 20... | Intercomputer, Inc. |
| Tape Loading System Eliminate the frustration of tape loading. LED indicators show high volume or low/noisy tape. Earphone plug lets you monitor tape... | Compusa Corporation |
| Tape Recorder Interface Improves load signal level. | D. Bruce Electronics |
| Test and Alignment Cassette Helps align mono cassette recorder head for best results, check tape speed and path. | Hilderbay Ltd. |
| The Box Tape load aid; includes VU meter and remote pause switch. | Sconzo & Sons |
| The Hilderbay Loading Aid Simple device to determine proper volume setting for loading. | Hilderbay Ltd. |
| The Last Cassette/16K Fix Small modification reduces RAM pack noise at the signal source. Kit and instructions. 16K. | Cottage Technology |
| TS 2020 Cassette Recorder The 2020 cassette recorder was one of several peripherals matched the 2068 in design. A variation was also sold by... | Timex Computer Corporation |
| Visi-Load Tape Load Monitor Three step LED meter that monitors tape loading level with just a glance. Plugs inline between the computer and the... | H & H Electronics |
| Vu-Load Monitors tape output level; gives a positive SAVE induction; detects blank tape without disconnecting cassette wires. | L & G Enterprises |
| WIDGITAPE Standard cassette recorder modified for computer control. Offers file directory, read/write from programs. Uses endless loop tapes. | CAI Instruments, Inc. |
| Winky Board Passive filter that plugged into the cassette tape recorder to produce easier tape loading. Supported other functions such as a... | G. Russell Electronics |
| Winky Board 2 Tape interface that filters noise when saving for clean, easy loading tapes. Duplicate any cassette —even normally unsavable cassettes. Save... | G. Russell Electronics |
| Winky Board 2000 The Winky Board 2000 brought the same features of the Winky Board to TS 2068 users. It provided visual feedback... | G. Russell Electronics |
| Z-DUBBER The Z-DUBBER is an interface between the Sinclair computer and its cassette recorder which allowed even the most difficult cassette... | Bytesize Micro Technology |
| ZX-21 Metered Cassette Interface Cassette loading interface with VU meter. Reduce program load errors to a minimum by pre-setting your tape recorder to the... | Data-assette |
| ZX-22 Powered Cassette Interface Power driven cassette loading interface. This unit uses the power pack to test audio level and gives a red or... | Data-assette |
| ZX-99 Tape Control Automatic tape control (up to 4 units) and RS-232C printer interface. Built-in USR commands provide program control over the cassette... | Data-assette |